LETTER TO THE EDITOR

Altered RV Mechanics Post-LVAD Insertion: a Physiological Perspective!

Rohan MagoonI; Jes JoseII; Jasvinder Kaur KohliI; Ramesh KashavI

DOI: 10.21470/1678-9741-2020-0058

Intensive care of patients on left ventricular assist device (LVAD) support is compounded by the peculiar physiological consequences of circulatory assistance.

In this context, clinical deterioration in the right ventricular (RV) function is often encountered post-LVAD implantation, with an incidence of 9.4-44% and is associated with an elevated risk of mortality[1,2]. The key principles determining the RV mechanical alterations are series circulatory effects, ventricular interdependence, and ventriculoarterial coupling (Figure 1). Firstly, LVAD assistance rapidly restores the cardiac output, resulting in an augmented RV preload owing to a series circulation. Secondly, a rapid offloading of the left ventricle induced by the assist device results in a leftward interventricular septum shift, significantly reducing the septal contribution to RV contractility. This geometrical alteration and the consequential architectural disadvantage by the virtue of ventricular interdependence in background of an enhanced preload can unmask pre-existing RV dysfunction[3]. Therefore, subtle pre-LVAD RV dysfunction is an important determinant of subsequent significant contractile impairment culminating as RV failure.

Fig. 1 - The pathophysiology of post-left ventricular assist device (LVAD) right ventricular (RV) dysfunction. LV=left ventricular; PVR=pulmonary vascular resistance

Interestingly, the principle of ventriculoarterial coupling is central to the post-LVAD RV dynamics, with any degree of elevation in pulmonary vascular resistance proving to be detrimental in such scenario. This explains the rationale behind the administration of phosphodiesterase inhibitors and other non-pharmacological and ventilatory manipulations aimed at attenuating an elevated RV afterload.

The mortality attributable to post-LVAD RV failure is largely a consequence of decreased flow to the LVAD, leading to a significant reduction in pump output, compromising the endorgan perfusion[4]. The coexistent systemic venous congestion compounds the situation furthermore. In the most extreme form, the clinical situation mandates biventricular assistance. Therefore, the echocardiographic predictors of post-LVAD RV failure continue to be actively investigated in order to adequately and consistently define the involved risk. However, the role of serial echocardiography in assessing the degree of septal shift on LVAD support, tricuspid valvular competency, pulmonary arterial pressure, and the concomitant RV function with the titration of inotropic support cannot be overemphasized.

The aforementioned elucidation of the impact of altered RV mechanics on clinical outcomes post-LVAD insertion highlights the importance of a sound understanding of the underlying pathomechanisms as the basis of echocardiographic surveillance and subsequent therapeutic measures. This discussion is particularly pertinent in the current era of mechanical circulatory assistance, wherein LVAD support continues to evolve as a bridge to transplantation, destination therapy, or as a temporary circulatory support with an expectant recovery of the cardiac function for the ever-growing cohort of patients with advanced heart failure, exceeding the availability of potential organ donors by a considerably wide margin[5].

REFERENCES


1. Hayek S, Sims DB, Markham DW, Butler J, Kalogeropoulos AP. Assessment of right ventricular function in left ventricular assist device candidates. Circ Cardiovasc Imaging. 2014;7:379–89.

2. El-Banayosy A, Arusoglu L, Kizner L, Fey O, Minami K, Korfer R. Complications of circulatory assist. Perfusion. 2000;15:327-31.

3. Neragi-Miandoab S, Goldstein D, Bello R, Michler R, D'Alessandro D. Right ventricular dysfunction following continuous flow left ventricular assist device placement in 51 patients: predicators and outcomes. J Cardiothorac Surg. 2012;7:60.

4. Van Meter CH Jr. Right heart failure: best treated by avoidance. Ann Thorac Surg. 2001;71(suppl):S220-2.

5. Miller LW, Guglin M. Patient selection for ventricular assist devices: a moving target. J Am Coll Cardiol. 2013;61:1209–1221.

CCBY All scientific articles published at rbccv.org.br are licensed under a Creative Commons license

Indexes

All rights reserved 2017 / © 2024 Brazilian Society of Cardiovascular Surgery DEVELOPMENT BY